IPS CORP -- WELD-ON 3 FOR ACRYLIC -- 8040-00N042938
===================== Product Identification =====================
Product ID:WELD-ON 3 FOR ACRYLIC
MSDS Date:05/01/1991
FSC:8040
NIIN:00N042938
=== Responsible Party ===
Company Name:IPS CORP
Address:17109 S MAIN
Box:379
City:GARDENA
State:CA
ZIP:90248
Country:US
Info Phone Num:213-321-6515
Emergency Phone Num:213-484-5151;800-424-9300(CHEMTREC)
CAGE:EO483
=== Contractor Identification ===
Company Name:IPS CORP
Address:17109 S MAIN
Box:379
City:GARDENA
State:CA
ZIP:90248-5000
Country:US
Phone:213-321-6515/213484-5151
CAGE:EO483
Company Name:IPS CORPORATION
Address:17109 S. MAIN ST.,
Box:379
City:GARDENA
State:CA
ZIP:90248
Country:US
Phone:310-898-3300
CAGE:17510
============= Composition/Information on Ingredients =============
Ingred Name:ING 13: VINCINITY OF ARC WELING, OPEN FLAMES OR HOT
SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION (ING 15)
RTECS #:9999999ZZ
Ingred Name:ING 14: OF HCL AND/OR PHOSGENE .
RTECS #:9999999ZZ
Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III). VAP
DENS: 2.93. EVAP RATE: 14.5 (BUAC=1). BP: 104F
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 90%
OSHA PEL:500 PPM;1000 PPM, C
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:TRICHLOROETHYLENE (SARA III)
CAS:79-01-6
RTECS #:KX4550000
Fraction by Wt: 9%
OSHA PEL:100 PPM/100 STEL
ACGIH TLV:50 PPM/100,A5STEL;93
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:METHACRYLIC ACID,METHYL ESTER; (METHYL METHACRYLATE
MONOMER) (SARA III)
CAS:80-62-6
RTECS #:OZ5075000
Fraction by Wt: < 1.0%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:VOLATILE ORGANIC COMPOUNDS: 160 GM/LTR
RTECS #:9999999VO
Ingred Name:SUPP DATA: "DEGREASER'S FLUSH"; FLUSHING & REDDENING OF THE
FACE, NECK AND SHOULDERS. CHLOROCARBON MATLS HAVE (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5: HAVE PRODUCED SENSITIZATION OF THE MYOCARDIUM TO
EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR EFTS (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6: IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE SUSTAINING USES IN (ING 8)
RTECS #:9999999ZZ
Ingred Name:ING 7: HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS .
RTECS #:9999999ZZ
Other REC Limits:N/KJ
Ingred Name:SPILL PROC:INDOORS, TURN OFF HEATING AND/OR AIR
CONDITIONING SYSTEMS TO PREVENT VAPOR FROM CONTAM ENTIRE BUILDING.
RTECS #:9999999ZZ
Ingred Name:RESP PROT: SHORT TERM EXPOSURE GUIDELINES MAY BE EXCEEDED,
USE NIOSH/MSHA APPROVED POSITIVE PRESSURE SCBA. IN (ING 11)
RTECS #:9999999ZZ
Ingred Name:ING 10: CONFINED OR POORLY VENTILATED AREAS, USE NIOSH/MSHA
APPROVED POSITIVE PRESSURE SCBA.
RTECS #:9999999ZZ
Ingred Name:VENT: INGREDIENT SECTION. USE ONLY EXPLOSION PROOF
VENTILATION EQUIPMENT .
RTECS #:9999999ZZ
Ingred Name:OTHER PREC:HNDLG EQUIPMENT SHOULD BE ELECTRICALLY GROUNDED.
NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL(ING 14)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:EXPOSURE TO VAPS MAY CAUSE
RESP TRACT IRRIT, SIGNS OF NERV SYS DEPRESS (DROWSINESS, DIZZINESS,
NAUSEA, HEADACHE AND FATIGUE), ARRHYMIAS (IRREGULAR HEART BEAT).
EXPOSURE TO HIGH CONCS MAY I MPAIR THE BLOOD'S ABILITY TO TRANSPORT
OXYGEN. PRLNGD/RPTD EXPOS TO VAPS MAY CAUSE LIVER & KIDNEY DMG.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONOGRAPHS
SUPPLEMENT, VOL 7, PG 194, 1987: GRP 2B. NTP 6TH ANNUAL REPORT ON
CARCINS, (SUPP DATA
Effects of Overexposure:HLTH HAZ: SKIN:RPTD/PRLNGD CNTCT MAY CAUSE
IRRIT, DEFATTING OF SKIN AND DERMATITIS. MAY BE ABSORBED THROUGH
SKIN. INGEST: MAY CAUSE IRRIT TO DIGESTIVE TRACT, SIGNS OF NERV SYS
DEPRESS. IF VOMIT OCCURS , THIS PROD CAN BE ASPIRATED INTO
LUNGSCAUSING LUNG INFLAMM & DAMAGE. CHRONIC: CHRONIC EXPOS TO
METHYLENE (SUPP DATA)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
DISEASES OF THE LIVER, KIDNEY, OR HEART MAY HAVE INCREASED
SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE PATIENT TO FRESH AIR. ADMIN ARTF RESP. CALL
PHYSICIAN. EYE: IMMED FLUSH WITH PLENTY OF WATER FOR 15 MIN & GET
MED ATTN. SKIN: REMOVE CONTAM CLTHG & SHOES. WASH WITH SOAP AND
WATER. WASH C ONTAM CLTHG BEFORE REUSE. INGEST: DO NOT INDUCE
VOMITING. GIVE WATER OR MILK. CONTACT PHYSICIAN OR POISON CONTROL
CENTER IMMED. NOTE TO MD: DO NOT ADMIN SYMPATHOMIMETIC DRUGS UNLESS
ABSOLUTELY NEC.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CO2, FOAM. WATER MAY BE AN
INEFFECTIVE EXTINGUISHING AGENT.
Fire Fighting Procedures:THE USE OF NIOSH/MSHA APPRVD PRESS DEMAND SCBA
& FULL PROT EQUIP . IS RECOM FOR FIRE FIGHTERS. WATER SPRAY MAY BE
USEFUL IN MINIMIZING VAPORS &(SUPP DATA)
Unusual Fire/Explosion Hazard:AVOID HOT SURFACES AND OTHER SOURCES OF
IGNITION. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND
PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:EVAC AREA, VENT & AVOID BRTHG VAPS. DIKE AREA
TO CNTN SPILL. CLEAN UP AREA (WEAR PROT EQUIP) BY MOPPING OR
W/ABSORB MATL & PLACE IN CLOSED CNTNRS FOR DISP. AVOID CONTAM OF
GROUND & SURFACE WATERS. DO NOT FLUSH TO SEWER. IF SPILL OCCURS
(ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN SHADE BETWEEN 40-110F. KEEP
AWAY FROM HEAT, SPARKS, OPEN FLAME & OTHER SOURCES OF IGNITION.
AVOID PROLONGED BREATHING OF VAPORS.
Other Precautions:USE W/ADEQ VENT. AVOID CNTCT W/EYES, SKIN & CLTHG.
TRAIN EMPLOYEES ON ALL SPECIAL HNDLG PROC BEFORE THEY WORK W/THIS
PROD. FOLLOW ALL PREC INFO GIVEN ON CNTNR LABEL, PROD BULLETINS &
OUR OTHER CEMENTI NG LITERATURE. ALL HNDLG EQUIP (ING 13)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:ATMOSPHERIC LEVELS SHLD BE MAINTAINED BELOW
ESTAB EXPOS LIMITS CNTND IN INGRED SEC. IF AIRBORNE CONCS EXCEED
THOSE LIMITS, USE NIOSH/MSHA APPRVD SUPPLIED AIR RESP. DO NOT USE A
CHEM CARTRIDGE RESP. FO R EMERGENCY & OTHER CNDTNS WHERE(ING 10)
Ventilation:USE ONLY W/ADEQ VENT. PROVIDE SUFF VENT IN VOL & PATTERN TO
KEEP CONTAM BELOW APPLIC EXPOS LIMITS SET FORTH IN (ING 12)
Protective Gloves:PVA COATED OR LATEX - NITRILE RUBBER.
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:APRON AND A SOURCE OF RUNNING WATER TO FLUSH
OR WASH EYES AND SKIN IN CASE OF CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:COOLING CNTNRS EXPOSED TO HEAT & FLAME. AVOID SPREADING
BURNING LIQUID W/WATER USED FOR COOLING PURPOSES. CARCIN: 1991:
ANTICIPATED TO BE CARCINGEN. EFTS OF OVEREXP: CHLORIDE HAVE CAUS ED
LIVER & KIDNEY DISEASE IN EXPERIMENTAL ANIMALS. INGEST OF ALCOHOL
AFTER EXPOS OF TRICHLOROETHYLENE MAY CAUSE (ING 5)
================== Physical/Chemical Properties ==================
HCC:T4
Boiling Pt:B.P. Text:INGRED 1
Vapor Pres:390 @ 20C
Vapor Density:SEE ING
Spec Gravity:1.330 @ 73F
Evaporation Rate & Reference:SEE ING
Solubility in Water:SLIGHTLY MISCIBLE
Appearance and Odor:CLEAR, THIN LIQUID. CHARACTERISTIC ODOR OF
CHLORINATED SOLVENTS.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXYGEN, NITROGEN PEROXIDE, POTSSIUM AND REACTIVE
METALS.
Stability Condition to Avoid:AVOID CNTCT W/OPEN FLAME, ELEC ARCS, HOT
SURFACES WHICH CAN CAUSE THERMAL DECOMP. AVOID HEAT, SPARKS,
SOURCES OF IGNIT.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON
MONOXIDE, CARBON DIOXIDE, PHOSGENE AND/OR HYDROGEN CHLORIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:RECOVERED LIQUIDS MAY BE SENT TO A LICENSED
RECLAIMER OR INCINERATION FACILITY, CONTAMINATED MATERIAL MUST BE
DISPOSED OF IN A PERMITTED WASTE MANAGEMENT FACILITY. CONSULT
LOCAL, STATE AND FEDERAL AUT HORITIES FOR APPROVED PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.