CRYODYNE TECHNOLOGIES INC -- OXYGEN -- 6830-00N028106 <pre>===================== Product Identification ===================== Product ID:OXYGEN MSDS Date:03/01/1990 FSC:6830 NIIN:00N028106 === Responsible Party === Company Name:CRYODYNE TECHNOLOGIES INC Address:67 WINTHROP RD Box:233 City:CHESTER State:CT ZIP:06412 Country:US Info Phone Num:203-526-5000 Emergency Phone Num:203-526-5000 CAGE:0EHW9 === Contractor Identification === Company Name:CRYODYNE TECHNOLOGIES INC Address:67 WINTHROP RD Box:233 City:CHESTER State:CT ZIP:06412 Country:US Phone:203-526-5000 CAGE:0EHW9 ============= Composition/Information on Ingredients ============= Ingred Name:ING 10:COMPRESSED GASES. SHIPMENT OF COMPRESSED GAS CYLINDER WHICH HAS NOT BEEN FILLED BY OWNER/W/HIS (WRITTEN) (ING 12) RTECS #:9999999ZZ Ingred Name:ING 11: CONSENT IS IN VIOLATION OF FEDERAL LAW (49CFR). RTECS #:9999999ZZ Ingred Name:ING 9:PAMPHLET G-4.1. COMPRESSED GAS CYLINDERS SHOULD NOT BE REFILLED EXCEPT BY QUALIFIED PRODUCERS OF (ING 11) RTECS #:9999999ZZ Ingred Name:OXYGEN DIFLUORIDE CAS:7782-44-7 RTECS #:RS2060000 Ingred Name:WASTE DISP METH: INC. LOATION. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS . RTECS #:9999999ZZ Ingred Name:OTHER PREC:PROD FROM CYLINDER. USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT HAZ BACK FLOW INTO CYLINDER. (ING 4) RTECS #:9999999ZZ Ingred Name:ING 3:PROTECT CYLINDERS FROM PHYS DAM. STORE IN COOL/DRY/WELL-VENTD AREA AWAY FROM HEAVILY TRAFFICKED AREAS & (ING 5) RTECS #:9999999ZZ Ingred Name:ING 4:AWAY FROM FULL/EMPTY STORED CYLINDERS WHICH CNTN FLAMM PROD. DO NOT ALLOW TEMP WHERE CYLINDERS ARE STORED (ING 6) RTECS #:9999999ZZ Ingred Name:ING 5:TO EXCEED 130F. UPRIGHT & FIRMLY SECURED TO PVNT FALLING/BEING KNOCKED OVER. FULL & EMPTY CYLINDERS SHOULD (ING 7) RTECS #:9999999ZZ Ingred Name:ING 6:BE SEGRATED. USE A "FIRST IN-FIRST OUT" INVENTORY SYS TO PVNT FULL CYLINDERS BEING STORED FOR EXCESSIVE (ING 8) RTECS #:9999999ZZ Ingred Name:ING 7:PERIODS OF TIME. O*2 SHOULD NOT BE USED AS SUBSTITUTE FOR COMPRESSED AIR IN PNEUMATIC EQUIP SINCE THIS TYPE(ING 9) RTECS #:9999999ZZ Ingred Name:ING 8:GENERALLY FLAMM LUBRICANTS. EQUIP TO CNTN O*2 MUST BE "CLEANED FOR O*2 SERVICE. "SEE COMPRESSED GAS ASSOC (ING 10) RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:BREATHING HIGH CONCENTRATIONS (>75 MOLAR PERCENT) CAUSES SYMP OF HYPEROXIA WHICH INCLUDE CRAMPS, NAUSEA, DIZZINESS, HYPOTHERMIA, ANBIOPIA, RESPIRATORY DIFFICULTIES, BRADYCARDIA, FAINTING SPELLS & CON VULSIONS CAPABLE OF LEADING TO DEATH. Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INHAL:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO O*2. RESCUE PERS SHOULD BE COGNIZANT OF EXTREME FIRE HAZ ASSOC W/O*2-RICH ATM. CONSCIOUS PERSONS SHOULD BE ASSISTED TO AN UNCONTAMD AREA & BRTHE FRESH AIR. THEY SHOULD BE KEPT WARM & QUIET. PHYS SHOULD BE INFORMED THAT THE VICTIM IS EXPERIENCING (HAS EXPER) HYPEROXIA. UNCON PERSON SHOULD BE MOVED TO AN UNCONTAMD AREA & GIVEN (SUPP DATA) ===================== Fire Fighting Measures ===================== Extinguishing Media:COPIOUS QTY OF WATER FOR FIRES WITH O*2 AS THE OXIDIZER. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . IF POSSIBLE STOP FLOW OF O*2 WHICH IS SUPPORTING FIRE. Unusual Fire/Explosion Hazard:VIGOROUSLY ACCELERATES COMBUSTION. ================== Accidental Release Measures ================== Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN TO PURGE PIPING W/AN INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CONTAINER OR CONTAINER VALVE, CONT CLOSEST CRYODYNE TECH. INC. LOCATION. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:USE ONLY IN WELL-VENTD AREAS. VALVE PROT CAPS/VALVE OUTLET THREADED PLUGS MUST REMAIN IN PLACE UNLESS CONTR IS SECURED W/VALVE OUTLET PIPE TO USE PT. Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLINDERS. USE SUITABLE HAND TRUCK FOR CYLINDER MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYLINDER TO LOWER PRESS (<300PSIG) PIPING/SYS. DO NOT HEAT CYLINDER BY AN Y MEANS TO INCR DISCHARGE RATE OF(ING 3) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:LOCAL EXHAST: TO PREVENT ACCUMULATION ABOVE 25 MOLAR PERCENT. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRST AID PROC:ASSISTED RESP. WHEN BRTHG HAS BEEN RESTORED, TRTMT SHOULD BE AS ABOVE. CONTINUED TRTMT SHOULD BE SYMPTOMATIC & SUPPORTIVE. INGEST: CALL MD . EYES: IMMED FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MIN, SEEK ASSISTANCE FROM MD . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD . ================== Physical/Chemical Properties ================== HCC:G4 Boiling Pt:B.P. Text:-297F,-183C Melt/Freeze Pt:M.P/F.P Text:-361F,-218C Vapor Pres:70F Spec Gravity:1.11@70F Appearance and Odor:COLORLESS, ODORLESS AND TASTELESS GAS. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ALL FLAMMABLE MATERIALS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:NONE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF RESIDUAL/UNUSED QTY. RETURN IN SHIPPING CONTR PROPERLY LBLD, W/ANY VALVE OUTLET PLUGS/CAPS SECURED & VALVE PROT CAP IN PLACE TO CRYODYNE TECH. INC. FOR PROPER DISP. FOR EM ER DISP, CONT CLOSEST CRYODYNE TECH (ING 2) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.